Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599692

RESUMO

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Seguimentos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos
2.
Eur Heart J ; 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38554125

RESUMO

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.

5.
JACC Heart Fail ; 12(1): 164-177, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38176782

RESUMO

BACKGROUND: Data assessing the long-term safety and efficacy of mavacamten treatment for symptomatic obstructive hypertrophic cardiomyopathy are needed. OBJECTIVES: The authors sought to evaluate interim results from the EXPLORER-Long Term Extension (LTE) cohort of MAVA-LTE (A Long-Term Safety Extension Study of Mavacamten in Adults Who Have Completed EXPLORER-HCM; NCT03723655). METHODS: After mavacamten or placebo withdrawal at the end of the parent EXPLORER-HCM (Clinical Study to Evaluate Mavacamten [MYK-461] in Adults With Symptomatic Obstructive Hypertrophic Cardiomyopathy; NCT03470545), patients could enroll in MAVA-LTE. Patients received mavacamten 5 mg once daily; adjustments were made based on site-read echocardiograms. RESULTS: Between April 9, 2019, and March 5, 2021, 231 of 244 eligible patients (94.7%) enrolled in MAVA-LTE (mean age: 60 years; 39% female). At data cutoff (August 31, 2021) 217 (93.9%) remained on treatment (median time in study: 62.3 weeks; range: 0.3-123.9 weeks). At 48 weeks, patients showed improvements in left ventricular outflow tract (LVOT) gradients (mean change ± SD from baseline: resting: -35.6 ± 32.6 mm Hg; Valsalva: -45.3 ± 35.9 mm Hg), N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels (median: -480 ng/L; Q1-Q3: -1,104 to -179 ng/L), and NYHA functional class (67.5% improved by ≥1 class). LVOT gradients and NT-proBNP reductions were sustained through 84 weeks in patients who reached this timepoint. Over 315 patient-years of exposure, 8 patients experienced an adverse event of cardiac failure, and 21 patients had an adverse event of atrial fibrillation, including 11 with no prior history of atrial fibrillation. Twelve patients (5.2%) developed transient reductions in site-read echocardiogram left ventricular ejection fraction of <50%, resulting in temporary treatment interruption; all recovered. Ten patients discontinued treatment due to treatment-emergent adverse events. CONCLUSIONS: Mavacamten treatment showed clinically important and durable improvements in LVOT gradients, NT-proBNP levels, and NYHA functional class, consistent with EXPLORER-HCM. Mavacamten treatment was well tolerated over a median 62-week follow-up.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Insuficiência Cardíaca , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cardiomiopatia Hipertrófica/tratamento farmacológico , Volume Sistólico , Função Ventricular Esquerda
6.
Eur J Heart Fail ; 26(1): 177-189, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37989800

RESUMO

AIMS: Obesity is causally related to the development of heart failure with preserved ejection fraction (HFpEF) but complicates the diagnosis and treatment of this disorder. We aimed to determine the relationship between severity of obesity and clinical, echocardiographic and haemodynamic parameters in a large cohort of patients with documented HFpEF. METHODS AND RESULTS: The REDUCE LAP-HF II trial randomized 626 patients with ejection fraction ≥40% and exercise pulmonary capillary wedge pressure (PCWP) ≥25 mmHg to atrial shunt or sham procedure. We tested for associations between body mass index (BMI), clinical characteristics, cardiac structural and functional abnormalities, physical limitations, quality of life and outcomes with atrial shunt therapy. Overall, 60.9% of patients had BMI ≥30 kg/m2 . As the severity of obesity increased, symptoms (Kansas City Cardiomyopathy Questionnaire score) and 6-min walk distance worsened. More severe obesity was associated with lower natriuretic peptide levels despite more cardiac remodelling, higher cardiac filling pressures, and higher cardiac output. Lower cut points for E/e' were needed to identify elevated PCWP in more obese patients. Strain measurements in all four chambers were maintained as BMI increased. Pulmonary vascular resistance at rest and exercise decreased with higher BMI. Obesity was associated with more first and recurrent heart failure events. However, there was no significant interaction between obesity and treatment effects of the atrial shunt. CONCLUSIONS: Increasing severity of obesity was associated with greater cardiac remodelling, higher right and left ventricular filling pressures, higher cardiac output and increased subsequent heart failure events. Despite significant obesity, many HFpEF patients have preserved right heart and pulmonary vascular function and thus, may be appropriate candidates for atrial shunt therapy.


Assuntos
Flavinas , Insuficiência Cardíaca , Luciferases , Humanos , Volume Sistólico , Cateterismo Cardíaco , Remodelação Ventricular , Qualidade de Vida , Átrios do Coração , Obesidade/complicações , Função Ventricular Esquerda
7.
Catheter Cardiovasc Interv ; 102(7): 1364-1375, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37698335

RESUMO

BACKGROUND: Extremely large aortic valve anatomy is one of the remaining limitations leading to exclusion of patients for transcatheter aortic valve replacement (TAVR). AIMS: The newly approved Myval 32 mm device is designed for use in aortic annulus areas up to 840 mm2 . Here we want to share the initial worldwide experience with the device. METHODS AND RESULTS: Retrospective data were collected from 10 patients with aortic stenosis and very large annular anatomy (mean area 765.5 mm2 ), who underwent implantation with 32 mm Myval transcatheter heart valve at eight centers. Valve Academic Research Consortium-2 device success was achieved in all cases. Mild paravalvular leak was observed in three patients and two patients required new pacemaker implantation. One patient experienced retroperitoneal hemorrhage caused by the contralateral 6 F sheath and required surgical revision. No device-related complications, stroke, or death from any cause occurred within the 30-day follow-up period. In a studied cohort of 2219 consecutive TAVR-screened patients from a central European site, only 0.27% of patients showed larger anatomy than covered by the 32 mm Myval device by instructions for use without off-label use of overexpansion. This rate was significantly higher for the 34 mm Evolut Pro (1.8%) and 29 mm Sapien 3 (2.1%) devices. CONCLUSIONS: The Myval 32 mm prosthesis showed promising initial results in a cohort of patients who previously had to be excluded from TAVR. It is desirable that all future TAVR systems accommodate larger anatomy to allow optimal treatment of all patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos
8.
N Engl J Med ; 389(14): 1286-1297, 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37634145

RESUMO

BACKGROUND: Extracorporeal life support (ECLS) is increasingly used in the treatment of infarct-related cardiogenic shock despite a lack of evidence regarding its effect on mortality. METHODS: In this multicenter trial, patients with acute myocardial infarction complicated by cardiogenic shock for whom early revascularization was planned were randomly assigned to receive early ECLS plus usual medical treatment (ECLS group) or usual medical treatment alone (control group). The primary outcome was death from any cause at 30 days. Safety outcomes included bleeding, stroke, and peripheral vascular complications warranting interventional or surgical therapy. RESULTS: A total of 420 patients underwent randomization, and 417 patients were included in final analyses. At 30 days, death from any cause had occurred in 100 of 209 patients (47.8%) in the ECLS group and in 102 of 208 patients (49.0%) in the control group (relative risk, 0.98; 95% confidence interval [CI], 0.80 to 1.19; P = 0.81). The median duration of mechanical ventilation was 7 days (interquartile range, 4 to 12) in the ECLS group and 5 days (interquartile range, 3 to 9) in the control group (median difference, 1 day; 95% CI, 0 to 2). The safety outcome consisting of moderate or severe bleeding occurred in 23.4% of the patients in the ECLS group and in 9.6% of those in the control group (relative risk, 2.44; 95% CI, 1.50 to 3.95); peripheral vascular complications warranting intervention occurred in 11.0% and 3.8%, respectively (relative risk, 2.86; 95% CI, 1.31 to 6.25). CONCLUSIONS: In patients with acute myocardial infarction complicated by cardiogenic shock with planned early revascularization, the risk of death from any cause at the 30-day follow-up was not lower among the patients who received ECLS therapy than among those who received medical therapy alone. (Funded by the Else Kröner Fresenius Foundation and others; ECLS-SHOCK ClinicalTrials.gov number, NCT03637205.).


Assuntos
Oxigenação por Membrana Extracorpórea , Infarto do Miocárdio , Choque Cardiogênico , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Estudos Retrospectivos , Risco , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento , Revascularização Miocárdica
9.
Eur Heart J Digit Health ; 4(3): 225-235, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37265865

RESUMO

Aims: Identification of high-risk patients and individualized decision support based on objective criteria for rapid discharge after transcatheter aortic valve implantation (TAVI) are key requirements in the context of contemporary TAVI treatment. This study aimed to predict 30-day mortality following TAVI based on machine learning (ML) using data from the German Aortic Valve Registry. Methods and results: Mortality risk was determined using a random forest ML model that was condensed in the newly developed TAVI Risk Machine (TRIM) scores, designed to represent clinically meaningful risk modelling before (TRIMpre) and in particular after (TRIMpost) TAVI. Algorithm was trained and cross-validated on data of 22 283 patients (729 died within 30 days post-TAVI) and generalisation was examined on data of 5864 patients (146 died). TRIMpost demonstrated significantly better performance than traditional scores [C-statistics value, 0.79; 95% confidence interval (CI)] [0.74; 0.83] compared to Society of Thoracic Surgeons (STS) with C-statistics value 0.69; 95%-CI [0.65; 0.74]). An abridged (aTRIMpost) score comprising 25 features (calculated using a web interface) exhibited significantly higher performance than traditional scores (C-statistics value, 0.74; 95%-CI [0.70; 0.78]). Validation on external data of 6693 patients (205 died within 30 days post-TAVI) of the Swiss TAVI Registry confirmed significantly better performance for the TRIMpost (C-statistics value 0.75, 95%-CI [0.72; 0.79]) compared to STS (C-statistics value 0.67, CI [0.63; 0.70]). Conclusion: TRIM scores demonstrate good performance for risk estimation before and after TAVI. Together with clinical judgement, they may support standardised and objective decision-making before and after TAVI.

10.
Artigo em Inglês | MEDLINE | ID: mdl-37126621

RESUMO

Despite their remarkable performance, deep neural networks remain unadopted in clinical practice, which is considered to be partially due to their lack of explainability. In this work, we apply explainable attribution methods to a pre-trained deep neural network for abnormality classification in 12-lead electrocardiography to open this "black box" and understand the relationship between model prediction and learned features. We classify data from two public databases (CPSC 2018, PTB-XL) and the attribution methods assign a "relevance score" to each sample of the classified signals. This allows analyzing what the network learned during training, for which we propose quantitative methods: average relevance scores over a) classes, b) leads, and c) average beats. The analyses of relevance scores for atrial fibrillation and left bundle branch block compared to healthy controls show that their mean values a) increase with higher classification probability and correspond to false classifications when around zero, and b) correspond to clinical recommendations regarding which lead to consider. Furthermore, c) visible P-waves and concordant T-waves result in clearly negative relevance scores in atrial fibrillation and left bundle branch block classification, respectively. Results are similar across both databases despite differences in study population and hardware. In summary, our analysis suggests that the DNN learned features similar to cardiology textbook knowledge.

11.
ESC Heart Fail ; 10(4): 2307-2318, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37060191

RESUMO

AIMS: There is evidence to suggest that the subtype of aortic stenosis (AS), the degree of myocardial fibrosis (MF), and level of aortic valve calcification (AVC) are associated with adverse cardiac outcome in AS. Because little is known about their respective contribution, we sought to investigate their relative importance and interplay as well as their association with adverse cardiac events following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: One hundred consecutive patients with severe AS and indication for TAVR were prospectively enrolled between January 2017 and October 2018. Patients underwent transthoracic echocardiography, multidetector computed tomography, and left ventricular endomyocardial biopsies at the time of TAVR. The final study cohort consisted of 92 patients with a completed study protocol, 39 (42.4%) of whom showed a normal ejection fraction (EF) high-gradient (NEFHG) AS, 13 (14.1%) a low EF high-gradient (LEFHG) AS, 25 (27.2%) a low EF low-gradient (LEFLG) AS, and 15 (16.3%) a paradoxical low-flow, low-gradient (PLFLG) AS. The high-gradient phenotypes (NEFHG and LEFHG) showed the largest amount of AVC (807 ± 421 and 813 ± 281 mm3 , respectively) as compared with the low-gradient phenotypes (LEFLG and PLFLG; 503 ± 326 and 555 ± 594 mm3 , respectively, P < 0.05). Conversely, MF was most prevalent in low-output phenotypes (LEFLG > LEFHG > PLFLG > NEFHG, P < 0.05). This was paralleled by a greater cardiovascular (CV) mortality within 600 days after TAVR (LEFLG 28% > PLFLG 26.7% > LEFHG 15.4% > NEFHG 2.5%; P = 0.023). In patients with a high MF burden, a higher AVC was associated with a lower mortality following TAVR (P = 0.045, hazard ratio 0.261, 95% confidence interval 0.07-0.97). CONCLUSIONS: MF is associated with adverse CV outcome following TAVR, which is most prevalent in low EF situations. In the presence of large MF burden, patients with large AVC have better outcome following TAVR. Conversely, worse outcome in large MF and relatively little AVC may be explained by a relative prominence of an underlying cardiomyopathy. The better survival rates in large AVC patients following TAVR indicate TAVR induced relief of severe AS-associated pressure overload with subsequently improved outcome.


Assuntos
Estenose da Valva Aórtica , Cardiomiopatias , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Fibrose
12.
Eur J Heart Fail ; 25(3): 322-331, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36691723

RESUMO

AIMS: The REDUCE-LAP II trial demonstrated adverse outcomes after interatrial shunt device (IASD) placement in heart failure with preserved ejection fraction (HFpEF) attributed to latent pulmonary vascular disease (PVD). We hypothesized that exercise stress cardiovascular magnetic resonance (CMR) imaging could provide non-invasive characterization of cardiac and pulmonary physiology for improved patient selection. METHODS AND RESULTS: The HFpEF-Stress trial prospectively enrolled 75 patients with exertional dyspnoea and diastolic dysfunction. Patients underwent rest and exercise stress right heart catheterization, echocardiography and CMR imaging. Pulmonary artery and capillary wedge pressures, cardiac index (CI) and pulmonary vascular resistance (PVR) were calculated. Latent PVD was defined as increased PVR ≥ 1.74 Wood units during exercise stress. CMR assessed long-axis strains (LAS) and filling volumes of all cardiac chambers. Right ventricular (RV) function was further quantified by stroke and peak flow volumes. Patients with latent PVD (n = 24) showed lower RV function (rest tricuspid annular plane systolic excursion, p = 0.010; stress RV LAS, p < 0.001) compared to patients without (n = 43). During exercise stress, RV stroke and peak flow volumes (p < 0.001) were reduced and led to impaired left atrial filling (p = 0.040) with a strong statistical trend to impaired ventricular (LV) filling (p = 0.098). This subsequently resulted in reduced LV-CI (p < 0.001) despite preserved LV systolic function (LV LAS p ≥ 0.255). The degree of RV dysfunction during exercise stress best predicted latent PVD (RV peak flow, area under the curve at rest 0.73 vs. stress 0.89, p = 0.004). CONCLUSIONS: Latent PVD is a feature of HFpEF and is associated with impaired RV functional reserve, global diastolic filling and LV-CI. This can be quantified by CMR and used to identify patients likely to benefit from IASD implantation.


Assuntos
Insuficiência Cardíaca , Acidente Vascular Cerebral , Humanos , Insuficiência Cardíaca/complicações , Ventrículos do Coração , Pressão Propulsora Pulmonar , Volume Sistólico/fisiologia , Função Ventricular Esquerda
13.
Sci Rep ; 12(1): 21430, 2022 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-36509862

RESUMO

Transcatheter aortic valve replacement (TAVR) has become the standard treatment for aortic stenosis in older patients. It increasingly relies on accurate pre-procedural planning using multidetector computed tomography (MDCT). Since little is known about the required competence levels for MDCT analyses, we comprehensively assessed MDCT TAVR planning reproducibility and accuracy with regard to valve selection in various healthcare workers. 20 randomly selected MDCT of TAVR patients were analyzed using dedicated software by healthcare professionals with varying backgrounds and experience (two structural interventionalists, one imaging specialist, one cardiac surgeon, one general physician, and one medical student). Following the analysis, the most appropriate Edwards SAPIEN 3™ and Medtronic CoreValve valve size was selected. Intra- and inter-observer variability were assessed. The first structural interventionalist was considered as reference standard for inter-observer comparison. Excellent intra- and inter-observer variability was found for the entire group in regard to the MDCT measurements. The best intra-observer agreement and reproducibility were found for the structural interventionalist, while the medical student had the lowest reproducibility. The highest inter-observer agreement was between both structural interventionalists, followed by the imaging specialist. As to valve size selection, the structural interventionalist showed the highest intra-observer reproducibility, independent of the brand of valve used. Compared to the reference structural interventionalist, the second structural interventionalist showed the highest inter-observer agreement for valve size selection [ICC 0.984, 95% CI 0.969-0.991] followed by the cardiac surgeon [ICC 0.947, 95%CI 0.900-0.972]. The lowest inter-observer agreement was found for the medical student [ICC 0.507, 95%CI 0.067-0.739]. While current state-of-the-art MDCT analysis software provides excellent reproducibility for anatomical measurements, the highest levels of confidence in terms of valve size selection were achieved by the performing interventional physicians. This was most likely attributable to observer experience.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Tomografia Computadorizada Multidetectores/métodos , Reprodutibilidade dos Testes , Desenho de Prótese , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Variações Dependentes do Observador , Estudos Retrospectivos , Valor Preditivo dos Testes
14.
J Mol Cell Cardiol ; 173: 1-15, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36084744

RESUMO

The incidence of aortic valve stenosis (AS), the most common reason for aortic valve replacement (AVR), increases with population ageing. While untreated AS is associated with high mortality, different hemodynamic subtypes range from normal left-ventricular function to severe heart failure. However, the molecular nature underlying four different AS subclasses, suggesting vastly different myocardial fates, is unknown. Here, we used direct proteomic analysis of small left-ventricular biopsies to identify unique protein expression profiles and subtype-specific AS mechanisms. Left-ventricular endomyocardial biopsies were harvested from patients during transcatheter AVR, and inclusion criteria were based on echocardiographic diagnosis of severe AS and guideline-defined AS-subtype classification: 1) normal ejection fraction (EF)/high-gradient; 2) low EF/high-gradient; 3) low EF/low-gradient; and 4) paradoxical low-flow/low-gradient AS. Samples from non-failing donor hearts served as control. We analyzed 25 individual left-ventricular biopsies by data-independent acquisition mass spectrometry (DIA-MS), and 26 biopsies by histomorphology and cardiomyocytes by STimulated Emission Depletion (STED) superresolution microscopy. Notably, DIA-MS reliably detected 2273 proteins throughout each individual left-ventricular biopsy, of which 160 proteins showed significant abundance changes between AS-subtype and non-failing samples including the cardiac ryanodine receptor (RyR2). Hierarchical clustering segregated unique proteotypes that identified three hemodynamic AS-subtypes. Additionally, distinct proteotypes were linked with AS-subtype specific differences in cardiomyocyte hypertrophy. Furthermore, superresolution microscopy of immunolabeled biopsy sections showed subcellular RyR2-cluster fragmentation and disruption of the functionally important association with transverse tubules, which occurred specifically in patients with systolic dysfunction and may hence contribute to depressed left-ventricular function in AS.


Assuntos
Estenose da Valva Aórtica , Transplante de Coração , Implante de Prótese de Valva Cardíaca , Humanos , Implante de Prótese de Valva Cardíaca/métodos , Volume Sistólico , Microscopia , Proteômica , Canal de Liberação de Cálcio do Receptor de Rianodina , Doadores de Tecidos , Valva Aórtica , Função Ventricular Esquerda/fisiologia , Biópsia , Resultado do Tratamento
15.
J Cardiovasc Magn Reson ; 24(1): 45, 2022 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-35897100

RESUMO

BACKGROUND: Since cardiovascular magnetic resonance (CMR) imaging allows comprehensive quantification of both myocardial function and structure we aimed to assess myocardial remodeling processes in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). METHODS: CMR imaging was performed in 40 patients with severe AS before and 1 year after TAVR. Image analyses comprised assessments of myocardial volumes, CMR-feature-tracking based atrial and ventricular strain, myocardial T1 mapping, extracellular volume fraction-based calculation of left ventricular (LV) cellular and matrix volumes, as well as ischemic and non-ischemic late gadolinium enhancement analyses. Moreover, biomarkers including NT-proBNP as well as functional and clinical status were documented. RESULTS: Myocardial function improved 1 year after TAVR: LV ejection fraction (57.9 ± 16.9% to 65.4 ± 14.5%, p = 0.002); LV global longitudinal (- 21.4 ± 8.0% to -25.0 ± 6.4%, p < 0.001) and circumferential strain (- 36.9 ± 14.3% to - 42.6 ± 11.8%, p = 0.001); left atrial reservoir (13.3 ± 6.3% to 17.8 ± 6.7%, p = 0.001), conduit (5.5 ± 3.2% to 8.4 ± 4.6%, p = 0.001) and boosterpump strain (8.2 ± 4.6% to 9.9 ± 4.2%, p = 0.027). This was paralleled by regression of total myocardial volume (90.3 ± 21.0 ml/m2 to 73.5 ± 17.0 ml/m2, p < 0.001) including cellular (55.2 ± 13.2 ml/m2 to 45.3 ± 11.1 ml/m2, p < 0.001) and matrix volumes (20.7 ± 6.1 ml/m2 to 18.8 ± 5.3 ml/m2, p = 0.036). These changes were paralleled by recovery from heart failure (decrease of NYHA class: p < 0.001; declining NT-proBNP levels: 2456 ± 3002 ng/L to 988 ± 1222 ng/L, p = 0.001). CONCLUSION: CMR imaging enables comprehensive detection of myocardial remodeling in patients undergoing TAVR. Regression of LV matrix volume as a surrogate for reversible diffuse myocardial fibrosis is accompanied by increase of myocardial function and recovery from heart failure. Further data are required to define the value of these parameters as therapeutic targets for optimized management of TAVR patients. Trial registration DRKS, DRKS00024479. Registered 10 December 2021-Retrospectively registered, https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00024479.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Meios de Contraste , Gadolínio , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Estudos Prospectivos , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
17.
Stud Health Technol Inform ; 283: 39-45, 2021 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-34545818

RESUMO

Automatic electrocardiogram (ECG) analysis has been one of the very early use cases for computer assisted diagnosis (CAD). Most ECG devices provide some level of automatic ECG analysis. In the recent years, Deep Learning (DL) is increasingly used for this task, with the first models that claim to perform better than human physicians. In this manuscript, a pilot study is conducted to evaluate the added value of such a DL model to existing built-in analysis with respect to clinical relevance. 29 12-lead ECGs have been analyzed with a published DL model and results are compared to build-in analysis and clinical diagnosis. We could not reproduce the results of the test data exactly, presumably due to a different runtime environment. However, the errors were in the order of rounding errors and did not affect the final classification. The excellent performance in detection of left bundle branch block and atrial fibrillation that was reported in the publication could be reproduced. The DL method and the built-in method performed similarly good for the chosen cases regarding clinical relevance. While benefit of the DL method for research can be attested and usage in training can be envisioned, evaluation of added value in clinical practice would require a more comprehensive study with further and more complex cases.


Assuntos
Fibrilação Atrial , Aprendizado Profundo , Diagnóstico por Computador , Eletrocardiografia , Humanos , Projetos Piloto
18.
EuroIntervention ; 17(10): 809-817, 2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34031021

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) has limited treatment options and is associated with high morbidity and mortality. AIMS: We evaluated the safety and effectiveness of the Cardioband tricuspid valve reconstruction system from the ongoing European single-arm, multicentre, prospective TriBAND post-market clinical follow-up study. METHODS: Eligible patients had chronic symptomatic functional TR despite diuretic therapy and were deemed candidates for transcatheter tricuspid repair by the local Heart Team. RESULTS: Sixty-one patients had ≥severe functional TR. At baseline, 85% of patients were in NYHA Class III-IV, 94% had ≥severe TR (core laboratory-assessed) with 6.8% EuroSCORE II and 53% LVEF. Device success was 96.7%. At discharge, 59% (p<0.001) of patients achieved ≤moderate TR and 78% had at least one grade TR reduction. At 30 days, all-cause mortality and composite MAE rates were 1.6% and 19.7%, respectively; septolateral annular diameter was reduced by 20%, where 69% of patients achieved ≤moderate TR and 85% of patients had at least one grade TR reduction (all p<0.001). Mid-RVEDD, RA volume, and IVC diameter decreased by 10% (p=0.005), 21% (p<0.001), and 11% (p=0.022), respectively; 74% were in NYHA Class I-II (p<0.001) with improvements in overall KCCQ score by 17 points (p<0.001). CONCLUSIONS: In the TriBAND study, the Cardioband tricuspid system demonstrated favourable outcomes at discharge and 30 days in a challenging patient population with symptomatic ≥severe functional TR. Results showed significant reductions in annular diameter and TR severity, accompanied by early evidence of right heart remodelling and improvements in functional status and quality of life.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
19.
Circulation ; 143(15): 1484-1498, 2021 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-33472397

RESUMO

BACKGROUND: Right heart catheterization using exercise stress is the reference standard for the diagnosis of heart failure with preserved ejection fraction (HFpEF) but carries the risk of the invasive procedure. We hypothesized that real-time cardiac magnetic resonance (RT-CMR) exercise imaging with pathophysiologic data at excellent temporal and spatial resolution may represent a contemporary noninvasive alternative for diagnosing HFpEF. METHODS: The HFpEF-Stress trial (CMR Exercise Stress Testing in HFpEF; URL: https://www.clinicaltrials.gov; Unique identifier: NCT03260621. URL: https://dzhk.de/; Unique identifier: DZHK-17) prospectively recruited 75 patients with echocardiographic signs of diastolic dysfunction and dyspnea on exertion (E/e'>8, New York Heart Association class ≥II) to undergo echocardiography, right heart catheterization, and RT-CMR at rest and during exercise stress. HFpEF was defined according to pulmonary capillary wedge pressure (≥15 mm Hg at rest or ≥25 mm Hg during exercise stress). RT-CMR functional assessments included time-volume curves for total and early (1/3) diastolic left ventricular filling, left atrial (LA) emptying, and left ventricular/LA long axis strain. RESULTS: Patients with HFpEF (n=34; median pulmonary capillary wedge pressure at rest, 13 mm Hg; at stress, 27 mm Hg) had higher E/e' (12.5 versus 9.15), NT-proBNP (N-terminal pro-B-type natriuretic peptide; 255 versus 75 ng/L), and LA volume index (43.8 versus 36.2 mL/m2) compared with patients with noncardiac dyspnea (n=34; rest, 8 mm Hg; stress, 18 mm Hg; P≤0.001 for all). Seven patients were excluded because of the presence of non-HFpEF cardiac disease causing dyspnea on imaging. There were no differences in RT-CMR left ventricular total and early diastolic filling at rest and during exercise stress (P≥0.164) between patients with HFpEF and noncardiac dyspnea. RT-CMR revealed significantly impaired LA total and early (P<0.001) diastolic emptying in patients with HFpEF during exercise stress. RT-CMR exercise stress LA long axis strain was independently associated with HFpEF (adjusted odds ratio, 0.657 [95% CI, 0.516-0.838]; P=0.001) after adjustment for clinical and imaging measures and emerged as the best predictor for HFpEF (area under the curve at rest 0.82 versus exercise stress 0.93; P=0.029). CONCLUSIONS: RT-CMR allows highly accurate identification of HFpEF during physiologic exercise and qualifies as a suitable noninvasive diagnostic alternative. These results will need to be confirmed in multicenter prospective research studies to establish widespread routine clinical use. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03260621. URL: https://dzhk.de/; Unique identifier: DZHK-17.


Assuntos
Teste de Esforço/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico , Imageamento por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Am Heart J ; 234: 1-11, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33428901

RESUMO

BACKGROUND: In acute myocardial infarction complicated by cardiogenic shock the use of mechanical circulatory support devices remains controversial and data from randomized clinical trials are very limited. Extracorporeal life support (ECLS) - venoarterial extracorporeal membrane oxygenation - provides the strongest hemodynamic support in addition to oxygenation. However, despite increasing use it has not yet been properly investigated in randomized trials. Therefore, a prospective randomized adequately powered clinical trial is warranted. STUDY DESIGN: The ECLS-SHOCK trial is a 420-patient controlled, international, multicenter, randomized, open-label trial. It is designed to compare whether treatment with ECLS in addition to early revascularization with percutaneous coronary intervention or alternatively coronary artery bypass grafting and optimal medical treatment is beneficial in comparison to no-ECLS in patients with severe infarct-related cardiogenic shock. Patients will be randomized in a 1:1 fashion to one of the two treatment arms. The primary efficacy endpoint of ECLS-SHOCK is 30-day mortality. Secondary outcome measures such as hemodynamic, laboratory, and clinical parameters will serve as surrogate endpoints for prognosis. Furthermore, a longer follow-up at 6 and 12 months will be performed including quality of life assessment. Safety endpoints include peripheral ischemic vascular complications, bleeding and stroke. CONCLUSIONS: The ECLS-SHOCK trial will address essential questions of efficacy and safety of ECLS in addition to early revascularization in acute myocardial infarction complicated by cardiogenic shock.


Assuntos
Oxigenação por Membrana Extracorpórea , Infarto do Miocárdio/terapia , Revascularização Miocárdica/métodos , Ponte de Artéria Coronária/métodos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Fibrinolíticos/uso terapêutico , Humanos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Prognóstico , Estudos Prospectivos , Qualidade de Vida , Tamanho da Amostra , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...